Static reactive power generators (FT-SVG series)

Static reactive power generators (FT-SVG series)

Views:


Category:

Download:

Product Introduction

Product Description:

Areas of application .

◇The Kscap SVG series of three-phase load unbalance automatic regulating devices is based on the concepts of intelligence, environmental protection, energy saving and safety.

The Kscap SVG series is based on the concepts of intelligence, environmental protection, energy saving and safety, with industrial grade design and national manufacturing standards, and is fully adaptable to various conditions of indoor and outdoor use.

 

Product Features

◇Real-time dynamic three-phase load imbalance automatic adjustment

◇Inductive or capacitive power factor compensation

◇Dynamic voltage regulation support

◇Harmonic filtering of the 2nd to 31st harmonics

◇Telemetry, telecommunication and remote control functions can be realized at the same time

◇All-round event record, no loss in power failure, 500 events

◇5-inch high-definition touch screen, real-time display of power distribution data

◇Supporting remote online upgrade of background system software

 3536a1.jpg

 

2.png

Principle of operation

Three-phase unbalance compensation principle.

◇The system current signal is collected in real time through an external special CT, and is quickly analysed and processed by the internal special detection circuit and controller to determine the three-phase unbalance of the system, and at the same time calculate the three-phase balanced conversion current value, and send a signal to drive the IGBT module to work to transfer the unbalanced current from the phase with the remaining current offset to the phase with the insufficient current offset.

◇In the case of an unbalanced load, the current of the grid is adjusted to a balanced state of 100A, where the load of phase A is 52A. In the case of unbalanced power consumption on the load side, the three-phase current of the grid is balanced.

 

3536a3.png

Voltage support principle.

◇Sampling through the compensation voltage point, when the internal controller gets the voltage information data, it immediately analyzes and processes the compensation point voltage information to determine whether the compensation point voltage exceeds the set value, when the voltage is lower than the set lower limit (Umin) value, it outputs capacitive current to raise the voltage, when the voltage is higher than the set upper limit (Umax) value, it outputs inductive current to lower the voltage, so as to realize the voltage of each phase The voltage of each phase is thus stabilised within the normal range.

3536a4.png

 

Harmonic filtering principle.

◇The IGBT inverts the current of the load with the same size and phase opposite current to achieve harmonic filtering.

3536a5.jpg

3536a6.jpg

 

 Principle of reactive power compensation.

◇When the system power factor is lower than the set power factor target value, the device instantaneously sends out inductive or capacitive reactive current to inject into the system to achieve the purpose of dynamic reactive power compensation, under the intelligent decision of the internal controller, through the real-time collection of load-side system current signals by an external special CT to ensure the best compensation effect of the system.

3738a1.png

                

 

 

Technical specifications                                                                                                          

Model number SVG
Performance indicators  
Operating voltage 400V (±20%)
Operating frequency 50Hz/60Hz (±10%)
Power rating 30A-500A(35kvar~400kvar)
Filter function -
Filter range 2-50 times
Filtering capacity <5% THDI (rated capacity)
Compensation function -
Range of reactive power compensation -0.98~+1 (adjustable)
Reactive power compensation capacity >99% (rated capacity)
Unbalance function -
Unbalance adjustment range Split-phase power factor 0.95 to 1 (within capacity range)
Imbalance adjustment capacity Unbalance ≦3% (within capacity)
Response time < 1ms
Full response time < 10ms
Switching frequency 20kHz
Overload protection -
Display operations  
5" touch screen -
Show content Current parameters/expert parameters/main wiring diagrams/event logs/wave curves etc.
Display language Chinese/English etc.
Mode of operation Panel touch/automatic hand switch
Communication methods  
Hardware interfaces RS485/Ethenet, fibre optic (optional), 3G (optional)
Communication protocols Modbus, CDT
Environmental conditions  
Ambient temperature -25°C~55°C (can be customised to suit site)
Storage temperature -40°C-70°C
Relative temperature 95% max, no condensation
Elevation Below 1500m
Note: - stands for optional features, for more specifications please contact Fuchida

 

 

Design selection reference:

 

Distribution applications

End-of-pipe power distribution applications for public buildings
Transformer capacity

100~160

200~250

315~400

500~630

Rated incoming current (A)

100

160

250

400

Three-phase load unbalance automatic adjustment device (A)

 

50

 

75

 

100

 

125

Three-phase load unbalance automatic adjustment device (A)

 

15

 

25

 

35

 

50

Design reference list:

3940a2.png

 

 

image.png

 

 

image.png

 

 

image.png

 

3940a1.png

 

Installation wiring

4142a1.png

 