Low voltage iron core series reactors (FTE series)
Low voltage iron core series reactors (FTE series)
Views:
Category:
Download:
Product Introduction
The role of reactors
◇ Harmonic amplification is suppressed and a certain percentage of harmonics are filtered out.
◇ The precise matching of capacitor banks in series to form a passive filter allows for precise filtering of certain harmonics.
◇ Suppresses inrush currents when putting in capacitors and protects capacitors and other components.
Application
Low voltage series reactors, in series with capacitors to form reactive power compensation devices, for use in reactive power compensation and harmonic control systems.
Characteristics of reactors
1、 Low loss and
2、 High anti-harmonic capability, the
3、 High linearity to avoid magnetic saturation.
4、 Low noise operation, simple installation, environmental protection characteristics.
5、 Long service life with special temperature protection.
6, Reactors are single-phase and three-phase, both iron-core dry type.
The core is made of high quality low-loss silicon steel, and the core column is divided into small uniform sections by several air gaps, which are separated by epoxy glass cloth plates to ensure that the gaps in the reactor do not change during operation.
8. The coil and core of the reactor are assembled into a single unit and then cured through a process of pre-heating and vacuum lacquer dipping and hot baking, using imported lacquer impregnation, so that the coil and core of the reactor are firmly bonded together, which not only greatly reduces the noise during operation, but also has a very high heat resistance level, ensuring that the reactor can operate safely and noiselessly in a high temperature environment.
9. The exposed parts are treated with anti-corrosion treatment and the lead terminals are galvanised copper tube terminals.
10、 Our reactors are small in size, light in weight and beautiful in appearance.
Performance parameters
Rated voltage of mating capacitors | 0.25-0.69V |
Rated capacity (general purpose specification) | 5kvar - 60kvar |
Reactance | 6.0% - 14.0% |
Inductance deviation | 0 ≤ Ln ≤ 5% |
Phase number | Three phase, single phase |
Overcurrent | ≤1.35Ln |
Pressure resistance test | Windings to ground 3KV 1min |
Attrition | ≤15W/kvar |
Environment of use | -40°C to 50°C Humidity ≤ 90% |
Insulation class | Class F,H |
Noise | ≤48dB |
Protection class | IP00, indoor installation |
Mounting distance | >30mm |
Reference Standards | IEC19212 GB/T1094.6 |
Performance parameters
FTE three-phase series reactor selection
FTE three-phase series reactor selection | ||||||||||
Reactor type |
Capacitor rated capacity Qn |
Rated current In |
External dimensions (mm) | Remarks | ||||||
kvar |
A |
A |
B |
H |
E |
F |
||||
FTE-0.45-10-3/6 |
10kvar |
12.8 |
210 |
160 |
160 |
90 |
80 |
|||
FTE-0.45-15-3/6 |
15kvar |
19.2 |
210 |
170 |
165 |
90 |
85 |
|||
FTE-0.45-20-3/6 |
20kvar |
25.6 |
210 |
180 |
170 |
90 |
95 |
|||
FTE-0.45-25-3/6 |
25kvar |
32 |
220 |
180 |
190 |
90 |
103 |
|||
FTE-0.45-30-3/6 |
30kvar |
38.5 |
230 |
190 |
200 |
90 |
103 |
|||
FTE-0.45-40-3/6 |
40kvar |
51.3 |
250 |
200 |
200 |
90 |
115 |
|||
FTE-0.45-50-3/6 |
50kvar |
64 |
280 |
200 |
220 |
120 |
110 |
|||
FTE-0.45-60-3/6 |
60kvar |
77 |
280 |
200 |
230 |
120 |
120 |
|||
FTE three-phase series reactor selection | ||||||||||
Reactor type |
Capacitor rated capacity Qn |
Rated current In |
External dimensions (mm) | Remarks | ||||||
kvar |
A |
A |
B |
H |
E |
F |
||||
FTE-0.48-10-3/7 |
10kvar |
12 |
190 |
160 |
170 |
90 |
95 |
|||
FTE-0.48-15-3/7 |
15kvar |
18 |
210 |
160 |
180 |
90 |
95 |
|||
FTE-0.48-20-3/7 |
20kvar |
24 |
210 |
170 |
190 |
90 |
105 |
|||
FTE-0.48-25-3/7 |
25kvar |
30 |
220 |
170 |
190 |
90 |
102 |
|||
FTE-0.48-30-3/7 |
30kvar |
36 |
230 |
175 |
200 |
90 |
105 |
|||
FTE-0.48-40-3/7 |
40kvar |
48 |
220 |
190 |
210 |
90 |
120 |
|||
FTE-0.48-50-3/7 |
50kvar |
60 |
260 |
190 |
250 |
120 |
110 |
|||
FTE-0.48-60-3/7 |
60kvar |
72 |
260 |
200 |
250 |
120 |
120 |
|||
FTE three-phase series reactor selection | ||||||||||
Reactor type |
Capacitor rated capacity Qn |
Rated current In |
External dimensions (mm) | Remarks | ||||||
kvar |
A |
A |
B |
H |
E |
F |
||||
FTE-0.525-10-3/14 |
10kvar |
11 |
220 |
170 |
170 |
90 |
105 |
|||
FTE-0.525-15-3/14 |
15kvar |
16.5 |
230 |
180 |
200 |
90 |
110 |
|||
FTE-0.525-20-3/14 |
20kvar |
22 |
230 |
190 |
210 |
90 |
120 |
|||
FTE-0.525-25-3/14 |
25kvar |
27.5 |
250 |
200 |
210 |
90 |
127 |
|||
FTE-0.525-30-3/14 |
30kvar |
33 |
280 |
190 |
230 |
120 |
117 |
|||
FTE-0.525-40-3/14 |
40kvar |
44 |
290 |
200 |
240 |
120 |
130 |
|||
FTE-0.525-50-3/14 |
50kvar |
55 |
290 |
210 |
260 |
120 |
140 |
|||
FTE-0.525-60-3/14 |
60kvar |
66 |
290 |
220 |
260 |
120 |
150 |
|||
FTE single-phase series reactor selection | ||||||||||
Reactor type |
Capacitor rated capacity Qn |
Rated current In |
Dimensions | Remarks | ||||||
kvar |
A |
A |
B |
H |
E |
F |
||||
FTE-0.25-10-1/6 |
10kvar |
40 |
140 |
170 |
160 |
50 |
90 |
|||
FTE-0.25-12-1/6 |
12kvar |
48 |
140 |
180 |
170 |
50 |
100 |
|||
FTE-0.25-15-1/6 |
15kvar |
60 |
140 |
190 |
180 |
50 |
110 |
Model naming rules
-
- Low voltage iron core series reactors (FTE series)